Networking Nodes 32 Nuclear Radiation Detector NRD 100 with Relative Inherent Error Plus Minus 10 Percent 137Cs 1msv per Hour
| kesalahan inheren relatif | ≤ ± 10% (137cs 1msv/jam) | Node Jaringan | ≥32 |
|---|---|---|---|
| Nama Produk | Detektor Radiasi Nuklir | Area Deteksi Tangan | 200×120 Cm²×4 |
| Jenis alarm | Alarm Suara dan Visual | Sistem kendali jarak jauh | Ya |
| Suhu Kerja | - 10 ºC ~ + 45 ºC | Kisaran laju dosis | 10⁻⁶ Gy/jam – 10 Gy/jam |
| Menyoroti | Nuclear Radiation Detector NRD 100,32 Networking Nodes radiation monitor,137Cs radiation detector with warranty |
||
Product Description:
The Nuclear Radiation Detector is a state-of-the-art device designed to provide accurate and reliable measurements of nuclear radiation levels. Equipped with advanced technology, this detector is specifically engineered for alpha and beta ray data acquisition, making it an invaluable tool for environments where monitoring radiation is critical for safety and compliance. Utilizing a ZnS Coated Plastic Scintillator Detector, the device ensures high sensitivity and precision in detecting alpha and beta particles, which are essential for comprehensive radiation analysis.
One of the standout features of the Nuclear Radiation Detector is its efficient charging system, which supports both audible and visual indicators to notify users when the device is fully charged or still in the process of charging. This user-friendly feature enhances operational convenience and ensures that the detector is always ready for immediate deployment without guesswork or unnecessary delays.
The device boasts a networking capability that supports ≥32 networking nodes, allowing multiple detectors to be interconnected seamlessly. This feature is particularly useful in large-scale monitoring setups where data from various points need to be collected and analyzed collectively. With robust networking support, the Nuclear Radiation Detector facilitates comprehensive monitoring across extensive areas, providing a cohesive and integrated radiation detection system.
Accuracy is paramount in radiation detection, and this product meets stringent standards with a relative inherent error of ≤± 10% when measuring radiation at 1 mSv/h using a 137Cs source. This level of precision ensures that the data collected is reliable and can be trusted for both safety assessments and regulatory compliance. By maintaining consistent accuracy, the detector supports critical decision-making processes in nuclear facilities, research laboratories, and environmental monitoring stations.
Connectivity options are versatile with both USB and Bluetooth interfaces incorporated into the design. The USB interface allows for straightforward wired data transfer and device charging, while the Bluetooth connectivity enables wireless communication with computers, mobile devices, or centralized monitoring systems. This dual-interface approach provides flexibility in how users interact with the device and manage their radiation data, catering to various operational preferences and technological infrastructures.
The core detection element, a ZnS Coated Plastic Scintillator Detector, enhances the Nuclear Radiation Detector’s ability to perform alpha and beta ray data acquisition with remarkable efficiency. The ZnS coating is known for its sensitivity to alpha particles, while the plastic scintillator base supports beta particle detection, making the combination ideal for comprehensive radiation monitoring. This configuration improves detection sensitivity and response time, ensuring that even low levels of alpha and beta radiation are accurately recorded.
Features:
- Product Name: Nuclear Radiation Detector
- Working Temperature: -10 ºC ~ +45 ºC
- Remote Control System: Yes
- Detection Rays: X, γ, and Hard β Ray
- Charging Time: Audible and Visual Indicators
- Resolution: ≤3.5% (Cs-137@662keV)
- Functions as a surface contamination meter
- Detects Alpha and beta rays with continuous monitoring capability
- Continuously adjustable within the measuring range for precise readings
Technical Parameters:
| Product Name | Nuclear Radiation Detector |
| Model | NRD-100 |
| Detection Ray | X, γ and Hard β Ray |
| Hand Detection Area | 200×120 Cm² ×4 |
| Working Temperature | -10 ºC ~ +45 ºC |
| Protection Level | IP65 |
| Networking Nodes | ≥32 |
| Resolution | ≤3.5% (Cs-137@662keV) |
| Remote Control System | Yes |
| Alarm Type | Audible And Visual Alarm |
| Detector Type | ZnS Coated Plastic Scintillator Detector |
| Display | Large size touch screen |
Key Parameters:
Energy response: ≤ ±30% (@ Cs-137) from 30 keV to 1.5 MeV
-
Sensitivity: 11 cps per (µSv/h) (@ Cs-137)
-
Alarm threshold: Freely adjustable within range
-
Alarm modes: Audible, light, and vibration
-
Alarm response time: ≤ 8 seconds
-
Overload indication: Display overload from 100 ~ 1000 mSv/h; recovers within 5 seconds
-
Communication: Bluetooth
-
Power supply: Lithium battery (USB rechargeable)
-
Standby time: 120 hours under natural background radiation
-
Weight: 60 g
-
Dimensions: 60 mm × 46 mm × 20 mm
Applications:
The JOVI Nuclear Radiation Detector, model JVVMED-015, is an advanced and reliable instrument designed for a wide range of applications in radiation detection and measurement. Manufactured in China and certified with ISO9001, this detector ensures high quality and accuracy with a relative inherent error of ≤± 10% (137Cs 1msv/h). Its dose rate range of 10⁻⁶ Gy/h to 10 Gy/h, combined with a ZnS Coated Plastic Scintillator Detector, makes it highly sensitive and suitable for detecting even low levels of radiation.
This product is ideal for use in scenarios involving environmentally radioactive contamination assessment, where monitoring and controlling radioactive pollutants is critical to ensure safety and compliance with environmental standards. It serves as an effective surface contamination meter, capable of detecting radioactive particles on various surfaces, which is essential in nuclear power plants, laboratories, hospitals, and industrial environments where radioactive materials are handled.
The NRD-100 model is equipped with a remote control system, allowing users to operate the detector from a safe distance, minimizing exposure risks. It also features versatile data interfaces, including USB and Bluetooth, for seamless data transfer and integration with other monitoring systems. This functionality is crucial for real-time data analysis and reporting in professional radiation monitoring setups.
Because of its robust design and precise measurement capabilities, the JOVI JVVMED-015 is widely used in radiation safety inspections, emergency response to nuclear incidents, environmental monitoring, and contamination surveys. The detector comes securely packaged in a wooden case, ensuring safe transportation and delivery within 15 working days. With a minimum order quantity of just one piece and payment terms of T/T in advance, it is accessible for both individual and institutional needs.
Customization:
JOVI offers comprehensive product customization services for the Nuclear Radiation Detector, model number JVVMED-015. Manufactured in China and certified with ISO9001, this detector features a large size touch screen for easy operation and enhanced user experience. The core detection technology utilizes a ZnS Coated Plastic Scintillator Detector, ensuring high sensitivity and accuracy. With a resolution of ≤3.5% (Cs-137@662keV) and a relative inherent error of ≤±10% (137Cs 1msv/h), it guarantees reliable radiation measurements.
The detector supports data interface options including USB and Bluetooth, allowing seamless connectivity and data transfer. Its working temperature ranges from -10 ºC to +45 ºC, suitable for various environments. The hand detection area measures 200×120 Cm² ×4, providing extensive coverage for precise detection.
Packaging is done in a sturdy wooden case to ensure safe delivery, with a minimum order quantity of 1 piece. Delivery is promised within 15 working days, and payment terms are T/T in advance. JOVI’s customization services can tailor the ZnS Coated Plastic Scintillator Detector specifications and features to meet specific client requirements, ensuring optimal performance and satisfaction.
Packing and Shipping:
Product Packaging:
The Nuclear Radiation Detector is carefully packaged to ensure maximum protection during transit. The device is secured within a custom-molded foam insert to prevent movement and absorb shocks. This is enclosed in a sturdy, double-walled corrugated cardboard box, designed to withstand rough handling. All components, including the detector, charger, user manual, and accessories, are individually wrapped in anti-static and moisture-resistant materials to maintain product integrity.
Shipping:
We offer worldwide shipping with reliable carriers that provide tracking and insurance options. Each package is clearly labeled with handling instructions, including “Fragile” and “Handle with Care” notices to ensure careful transport. Shipping times vary by destination, typically ranging from 3 to 10 business days. Expedited shipping options are available for urgent needs. Customs documentation and regulatory compliance certificates are included as required for international shipments.
FAQ:
Q1: What is the brand and model number of the Nuclear Radiation Detector?
A1: The Nuclear Radiation Detector is branded as JOVI and the model number is JVVMED-015.
Q2: Where is the Nuclear Radiation Detector manufactured?
A2: The Nuclear Radiation Detector is made in China.
Q3: Does the Nuclear Radiation Detector have any certifications?
A3: Yes, the Nuclear Radiation Detector is certified with ISO9001.
Q4: What is the minimum order quantity for the Nuclear Radiation Detector?
A4: The minimum order quantity is 1 piece.